A remote DAQ system that works perfectly in the lab and fails in the field is not a remote DAQ system. It is a benchtop system that was deployed somewhere it was not designed to operate. The gap between those two things is where most remote DAQ planning failures happen, and it is almost always a gap in thinking through the hardware requirements, the network requirements, and the logging requirements for the actual deployment environment rather than the idealized one. At LabJack, we build DAQ hardware that engineers deploy in field sites, remote facilities, distributed monitoring systems, and other environments where the measurement point is not adjacent to a desk, and this guide covers what you actually need to plan before a remote DAQ deployment goes live.
A high-level overview follows. For the nitty-gritty, refer to the T-Series Datasheet and our Application Notes.
What Makes a DAQ System Genuinely Remote
Remote in DAQ system planning does not just mean physically distant from the office. It means the system operates in conditions where the assumptions that make benchtop DAQ easy, including reliable power, immediate physical access, a nearby computer, a stable network connection, and a person available to intervene when something goes wrong, do not all apply at the same time.
A monitoring system in an unmanned utility substation is remote. A test setup in a manufacturing cell, three buildings away from the engineering office, is remote. A weather station on a rooftop is remote. A measurement system in a vehicle test facility where the hardware needs to keep running through shift changes and weekends without someone restarting it is remote. What these scenarios share is that the system needs to handle conditions and contingencies that a supervised benchtop setup does not.
Planning a remote DAQ system means explicitly addressing each of the assumptions that benchtop setups take for granted and deciding how the system will handle the absence of those conditions. What is a DAQ system and the components that make it work covers the foundational DAQ system components before addressing remote-specific requirements.
Hardware Selection for Remote DAQ Deployments
Hardware selection for a remote DAQ system involves requirements that do not appear in benchtop specifications. The hardware needs to handle the environmental conditions of the deployment site, needs connectivity options that work in the network environment available at the site, needs power input flexibility if the power supply at the site differs from standard lab power, and, in many cases, needs to support some level of standalone operation rather than requiring a continuously connected host computer.
T-Series Hardware for Remote Deployments
The LabJack T-series devices are the appropriate hardware family for most remote DAQ deployments because they support Ethernet connectivity, support standalone operation through Lua scripting, and provide the analog input, digital I/O, and communication capabilities that remote measurement systems typically require.
The LabJack T7 supports USB and Ethernet connectivity with fourteen analog inputs, two analog outputs, and twenty-three digital I/O lines. Its Ethernet connectivity makes it suitable for network-connected remote deployments, and its Lua scripting capability allows important operations to happen locally without a continuously connected host computer.
The LabJack T7-Pro adds WiFi and a higher-resolution analog-to-digital converter to the T7's feature set. For remote deployments where running an Ethernet cable to the measurement point is impractical, the T7-Pro's WiFi connectivity provides a wireless alternative. The additional analog input resolution is relevant for remote monitoring applications where detecting small signal changes over long time periods is part of the measurement requirement.
The LabJack T8 provides eight high-resolution, simultaneously sampled analog inputs with channel-to-channel isolation and Ethernet connectivity, making it appropriate for remote deployments where analog signal quality and resolution are the primary measurement requirements. For applications involving precision voltage measurement, bridge circuits, or other signals where input resolution matters significantly, the T8's analog front end is worth considering.
For remote deployments with extensive analog input requirements, the MUX80 multiplexer expands the T7's analog input count to up to eighty channels, which is relevant for large-scale monitoring systems where many sensors need to connect to a single DAQ device at a remote site.
Terminal Boards and Signal Conditioning for Remote Installations
Remote installations benefit from organized, secure wiring that will not work loose over time due to vibration, thermal cycling, or incidental contact. Terminal boards provide convenient screw-terminal connections for sensors and signals'
The CB37 terminal board provides screw-terminal access to all signals on the T7's DB37 connector, which is the right approach for remote installations where wiring needs to be organized, labeled, and secured for the duration of the deployment. The CB15 terminal board provides the same organized terminal access for the DB15 connector.
For remote temperature measurement applications, the EI-1022 temperature probe and EI-1034 temperature probe are calibrated sensor options that connect directly to LabJack analog inputs. How to measure and log temperature with LabJack covers temperature measurement configuration for remote monitoring applications.
Power Considerations for Remote DAQ Hardware
Power availability at remote sites is not always the clean, stable supply that lab benches provide. Remote installations may need to run from DC power sources, may experience voltage variations that benchtop equipment does not, or may need to operate from battery or solar power in off-grid deployments.
The T-series devices are powered through their USB connector. The DC-to-DC power adapter is an accessory that supports flexible power input configurations for remote LabJack installations where the available power source differs from standard USB power.
Planning the power supply for a remote DAQ installation includes confirming the available voltage at the deployment site, identifying any voltage regulation or filtering that may be needed given the power quality at that site, and ensuring that the power supply will maintain operation through the power events that occur at that site over the deployment period.
Network Planning for Remote DAQ Systems
The network is where most remote DAQ deployments encounter their most persistent problems, because network conditions at remote sites are often significantly different from the stable, managed networks of an engineering office or lab environment.
Wired Ethernet for Remote Sites
Wired Ethernet is the most reliable network option for remote DAQ deployments where running a cable to the measurement point is feasible. Ethernet provides deterministic connection behavior, is not affected by wireless interference, and maintains connection stability through the kinds of conditions that affect WiFi performance in industrial and outdoor environments.
For remote sites where the DAQ hardware is fixed in place for an extended deployment, running an Ethernet cable from the hardware to a local switch or router is the approach that provides the most reliable network connectivity with the least ongoing management requirement. Standard Ethernet supports cable runs up to one hundred meters, which covers most within-facility remote deployment scenarios. Reliable Ethernet data acquisition and the practical considerations for networked deployments cover the Ethernet connectivity considerations for DAQ applications in more detail.
WiFi for Remote Sites Where Cabling Is Impractical
When running an Ethernet cable to the measurement point is not feasible, WiFi provides the connectivity that allows the remote DAQ system to communicate with the host computer or network without a physical cable. The T7-Pro's integrated WiFi is designed for exactly this scenario.
WiFi at remote sites requires planning beyond simply connecting to the nearest available network. Signal strength at the measurement point needs to be confirmed before deployment, not assumed based on signal strength at other locations in the facility. The access point infrastructure serving the remote site needs to be reliable enough to support continuous DAQ operation, which is a different requirement from the intermittent connectivity that most WiFi networks are designed around. Network security configuration needs to allow the DAQ device to communicate with the host system on the required ports.
For outdoor or structurally challenging remote sites where standard WiFi range is insufficient, directional antennas and access point placement planning may be necessary to ensure adequate signal strength at the measurement point throughout the deployment.
Network Security and Firewall Considerations
Remote DAQ systems that connect to facility networks need to be compatible with the network security policies that govern those networks. IT departments at industrial facilities increasingly apply the same security policies to measurement systems that they apply to other networked equipment, which can affect how DAQ devices are addressed, what ports are allowed through firewalls, and whether the devices can communicate directly with host computers or must route through specific network segments.
Engaging with the facility IT team early in the planning process, before hardware is purchased and installed, prevents the discovery of network security constraints after the system is physically deployed. Understanding the network topology, the firewall rules, and the IP address management approach at the remote site allows the DAQ system to be configured correctly from the start rather than requiring reconfiguration after deployment.
Environmental and Mechanical Considerations for Remote Installations
Remote DAQ hardware operates in environments that benchtop equipment does not encounter. Temperature extremes, humidity, dust, vibration, and accidental contact from personnel and equipment at the deployment site are all conditions that remote installations need to be planned for.
The T-series devices operate across a specified temperature range that covers most indoor industrial and facility environments. For outdoor deployments or environments with extreme temperature variation, enclosures that protect the electronics from environmental exposure while maintaining the thermal performance of the hardware are a necessary part of the installation plan.
Vibration from nearby machinery is a common condition in industrial remote deployments that can affect connector reliability and the mechanical integrity of wiring over time. Strain relief on sensor cables, secure mounting of the DAQ hardware, and terminal board connections rather than direct pin connections all contribute to vibration resistance in remote installations.
Physical access to the hardware for maintenance, configuration changes, and troubleshooting is a logistical consideration in remote deployments that benchtop setups do not have. Planning the installation with maintenance access in mind, including cable routing that allows individual cables to be replaced without disturbing the entire installation and mounting configurations that allow the hardware to be accessed without dismounting adjacent equipment, reduces the time and cost of servicing the system over the deployment lifetime.
Frequently Asked Questions About Remote DAQ Systems
What LabJack hardware is best suited for unattended remote deployments?
The T7 and T7-Pro are the most appropriate hardware for unattended remote deployments because they have Ethernet and optionally WiFi connectivity, and provide the analog and digital I/O capabilities that most remote monitoring applications require. The T7-Pro is the better choice when WiFi connectivity is needed or when higher analog input resolution is a requirement. For applications requiring high-resolution precision analog inputs, the T8 is worth evaluating.
How does standalone Lua scripting work for remote DAQ operation?
Lua scripts run directly on the T-series device's internal processor without requiring a connected host computer. The script can read analog and digital inputs, perform calculations, make control decisions, and write to analog and digital outputs. This makes the T7 and T7-Pro appropriate for deployments where network connectivity is intermittent or where the system needs to continue certain operations through network outages.
What network infrastructure does a remote Ethernet DAQ deployment require?
At minimum, a remote Ethernet DAQ deployment requires a switch or router that the DAQ device can connect to, an IP address for the device that is reachable from the host computer, and network connectivity between the remote site and the location where the host computer or logging server is running. In facility environments, this infrastructure is typically already in place. In field deployments, it may need to be created using a portable router or a direct connection between the DAQ device and a laptop. IT security policies at the facility need to be understood before deployment to ensure the DAQ device can communicate with the required systems.
What should I do if the remote site has unreliable power?
Unreliable power at a remote site requires planning for graceful recovery from power interruptions. Device configuration, Lua scripting capability, and smart software design are all tools you can use to allow the measurement application to restart automatically when power is restored, without requiring manual intervention. For sites with frequent power interruptions, an uninterruptible power supply that provides a buffer through short outages and a controlled shutdown through extended outages is worth including in the installation plan.
Where can I get help planning a remote DAQ system for my specific application?
The LabJack team can help with application-specific planning questions for remote deployments. Contact LabJack to discuss your measurement requirements, deployment environment, and connectivity constraints.
Plan the Remote System for Where It Will Actually Run
A remote DAQ system designed for the conditions it will actually face is a reliable infrastructure. One designed for idealized conditions is a source of frustrating field problems that are expensive to diagnose and fix from a distance. Working through the hardware, network, and logging requirements for the actual deployment environment before the system is built and installed is the investment that makes the difference between a system that runs reliably for its intended lifetime and one that requires constant attention. Browse the LabJack T-series devices to see the hardware options for remote deployments, or contact LabJack to discuss your specific application.