U3-LV | U3-HV | |
# Low-voltage AINs: | 16 | 12 |
# High-voltage AINs: | 0 | 4 |
#DIOs | 20 | 16 |
The U3-HV has the following differences versus the U3-LV:
- First 4 flexible I/O are changed to dedicated HV analog inputs.
- 4 HV inputs have ±10 volt or -10/+20 volt range.
- 12 LV inputs (flexible I/O) still available, for 16 total analog inputs.
OEM Versions
The U3-LV-OEM or U3-HV-OEM includes the board only without the enclosure and without most through-hole components. See Section 2.12 of the U3 Datasheet for more information.